Search results for "Semiconductor laser theory"
showing 10 items of 34 documents
Comparison of Single Event Transients Generated at Four Pulsed-Laser Test Facilities-NRL, IMS, EADS, JPL
2012
Four pulsed-laser single-event effects systems, differing in wavelength and pulse width, were used to generate single event transients in a large-area silicon photodiode and an operational amplifier (LM124) to determine how transient amplitude and charge collection varied among the different systems. The optical wavelength and the focused spot size are the primary factors influencing the resultant charge density profile. In the large-area photodiode the transients can be distorted by high charge-injection densities that occur for tightly focused, higher energy optical pulses. When the incident laser-pulse energies are corrected for reflection losses and photon efficiency, with collection de…
Diode laser welding of ABS: Experiments and process modeling
2009
International audience; The laser beam weldability of acrylonitrile/butadiene/styrene (ABS) plates is determined by combining both experimental and theoretical aspects. In modeling the process, an optical model is used to determine how the laser beam is attenuated by the first material and to obtain the laser beam profile at the interface. Using this information as the input data to a thermal model, the evolution of the temperature field within the two components can be estimated. The thermal model is based on the first principles of heat transfer and utilizes the temperature variation laws of material properties. Corroborating the numerical results with the experimental results, some impor…
Fine-structure mixing collisions of Rb(52D) excited in a two-photon transition using external-cavity cw diode laser
1999
We present an experimental study of fine structure (fs)- mixing in the 5 2 D state of Rb, and details of construction and performance of an external cavity cw diode laser, developed to provide a light source at 778 nm for two-photon excitation of Rb(5 2 D). Cross section for the fs-mixing Rb(5 2 D 5/2 ) yields Rb(5 2 D 3/2 ) in collisions with the ground state Rb(5 2 S 1/2 ) atoms was found to be 5.8 +/- 1.9 (DOT) 10 -14 cm 2 .
Triple-resonance autoionization of uranium optimized for diode laser excitation
2007
Abstract The photoionization of uranium via three-step excitation has been optimized for isotope selective trace analysis. A search found 13 new J = 6, 7, and 8 odd-parity states in the 36,850–37,200 cm− 1 region that allow blue–red–red three-photon excitation at wavelengths favorable for commercial diode laser systems. From each of these 13 states, near-threshold autoionization spectra were recorded at a resolution of 3 × 10− 4 cm− 1. Some 30 even-parity autoionizing levels with J = 5 to 9 have also been observed and characterized. Comparison of the spectra allows J assignment for the new intermediate levels as well as selection of an optimized path for trace analysis. We show that, for a …
Approaching the limits of multiple scattering decorrelation: 3D light-scattering apparatus utilising semiconductor lasers
2007
Light scattering as a function of scattering angle can be regarded as a standard method to investigate the dynamics of dilute colloidal suspensions. Concentrated suspensions, which are of interest if interactions between the particles are to be investigated, usually show strong multiple scattering. Decorrelation of multiple scattered light, which isolates single scattering events at the expense of a reduced signal-to-noise ratio, has been proven to work using the two-colour crosscorrelation scheme.
Label swapper device for spectral amplitude coded optical packet networks monolithically integrated on InP
2011
In this paper the design, fabrication and experimental characterization of an spectral amplitude coded (SAC) optical label swapper monolithically integrated on Indium Phosphide (InP) is presented. The device has a footprint of 4.8x1.5 mm 2 and is able to perform label swapping operations required in SAC at a speed of 155 Mbps. The device was manufactured in InP using a multiple purpose generic integration scheme. Compared to previous SAC label swapper demonstrations, using discrete component assembly, this label swapper chip operates two order of magnitudes faster. © 2011 Optical Society of America.
Current modulation induced stability in laser diode under high optical feedback strength
2021
The back-reflection of emitted laser beam (optical feedback, also know as selfmixing) from various external interfaces are sufficient to cause instability, and prohibiting its use in various fields such as communication, spectroscopy, imaging to name a few. So it is desirable to study the laser dynamics and the conditions causing it to be stable in spite of strong optical feedback. With the aid of mathematical formulation, simulation and backed by experimental evidences, it is demonstrated that the frequency deviation of the laser emission due to current (intensity) modulation alters the dynamic state and boundary conditions of the system such that even under large optical feedback strength…
Tunability of Injection Seeded High-Repetition Rate Ti:Sapphire Laser Far Off the Gain Peak
2009
We have investigated a tunability of a high‐repetition rate Ti:Sapphire laser seeded off the gain peak. By applying a birefringent filter, the 7 kHz injection seeded Ti:Sapphire laser system was operated with the average seeding efficiency of over 90% and the output power of over 1 W on the spectral range of 900–930 nm. We conclude that the birefringent filter suited for widely tunable operation of the injection seeded Ti:Sapphire laser system operated at high repetition rate.
Multi-spectral photoplethysmography technique for parallel monitoring of pulse shapes at different tissue depths
2011
A photoplethysmography (PPG) signal can provide very useful information about a subject's hemodynamic status in a hospital or home environment. A newly developed portable multi-spectral photoplethysmography device has been used for studies of 11 healthy subjects. Multi-spectral photoplethysmography (MS-PPG) biosensor intended for analysis of peripheral blood volume pulsations at different vascular depths has been designed and experimentally tested. Multi-spectral monitoring was performed by means of a three–wavelengths (405 nm, 660 nm and 780 nm) laser diode and a single photodiode with multi-channel signal output processing. The proposed methodology and potential clinical applications are …
1.65-μm Er:Yb:YAG diode-pumped laser delivering 80-mJ pulse energy
2005
We demonstrate efficient lasing of bulk diode-pumped Er 31 :Yb 31 :YAG at 1.645 mm. The material is transversely pumped using three quasi-cw 960-nm laser diode arrays in a simple arrangement. In the free-running mode of operation, an output pulse energy of 79 mJ is obtained at 4.7 J of incident optical pump energy. The lasing threshold lies in the range 1.0 to 1.9 J in long-pulse operation, depending on pumping conditions, and optical slope efficiencies of 2.2% to 3.4% were measured with respect to the incident pump energy. Furthermore, initial Q-switching experiments with a Co:MALO saturable absorber yielded pulses of 1.7-mJ energy and 340-ns FWHM duration. As the reported laser setup also…